Top of the page

Diatermo Monopolar / Bipolar 120D Electrosurgery Unit

Item No. 11-6560
Diatermo MB 120D is a high frequency electrosurgical unit suitable for minor and medium surgery. MB allow pure CUT, cut-coagulation BLEND, superficial coagulation FORCED COAG, deep coagulation in absence of necrosis SOFT COAG and, with forceps, BIPOLAR coagulation. The digital reading of delivered p

Description

Diatermo MB 120D is a high frequency electrosurgical unit suitable for minor and medium surgery.
 
MB allow pure CUT, cut-coagulation BLEND, superficial coagulation FORCED COAG, deep coagulation in absence of necrosis SOFT COAG and, with forceps, BIPOLAR coagulation.
 
The digital reading of delivered power and the monitoring of operative function by microcontroller guarantees absolute reliability of working conditions.
 
MB allow a highly professional surgery through ergonomic and safety features. The connection of neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode.
 
Possibility to control the output functions and the delivery of output power by the handle, allows the surgical operation without diverting attention from the surgical field.

Standard accessories

  • MB single use two button handle
  • Waterproof foot-switch (usable as alternative to handle)
  • MB flat neutral plate with cable
  • Kit of 10 short autoclavable electrodes, diameter 2.4mm
  • Power cable: 2m
  • User manual: GB, IT, available on request FR, ES, PL.

Features

  • Minimum invasive surgery
  • Possibility to use bipolar forceps
  • Possibility to use split neutral electrodes
  • Memorization of the last used settings
  • Power activation by pedal and/or handle
  • Digital adjustment and an indication of the output power
  • Adjustment of the acoustic indicator intensity 

Specifications

Max output power CUT  120 W - 250 Ohm
Max output power BLEND  90 W - 200 Ohm
Max output power FORCED COAG  80 W - 150 Ohm
Max output power SOFT COAG  60 W - 100 Ohm
Max output power BIPOLAR  40 W - 100 Ohm  
Working frequency  600 kHz  
Patient circuit  F
Selectable input voltage  115 - 230 Vac
Mains frequency  50 - 60 Hz  
Electrical input power  300 VA  
Size W x H x D254 x 104 x 288mm
Weight  5kgs
Controls  Patient/Plate circuit monitoring, Output power monitoring, Self-check control
Safety  EN60601-1, EN60601-1-2, EN60601-2-2
Electrical Class   I CF; MDD 93/42/EC Class: II b

Reviews (0)

There are no reviews yet.

Diatermo Monopolar / Bipolar 120D Electrosurgery Unit

Item No. 11-6560
Diatermo MB 120D is a high frequency electrosurgical unit suitable for minor and medium surgery. MB allow pure CUT, cut-coagulation BLEND, superficial coagulation FORCED COAG, deep coagulation in absence of necrosis SOFT COAG and, with forceps, BIPOLAR coagulation. The digital reading of delivered p

Description

Diatermo MB 120D is a high frequency electrosurgical unit suitable for minor and medium surgery.
 
MB allow pure CUT, cut-coagulation BLEND, superficial coagulation FORCED COAG, deep coagulation in absence of necrosis SOFT COAG and, with forceps, BIPOLAR coagulation.
 
The digital reading of delivered power and the monitoring of operative function by microcontroller guarantees absolute reliability of working conditions.
 
MB allow a highly professional surgery through ergonomic and safety features. The connection of neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode.
 
Possibility to control the output functions and the delivery of output power by the handle, allows the surgical operation without diverting attention from the surgical field.

Standard accessories

  • MB single use two button handle
  • Waterproof foot-switch (usable as alternative to handle)
  • MB flat neutral plate with cable
  • Kit of 10 short autoclavable electrodes, diameter 2.4mm
  • Power cable: 2m
  • User manual: GB, IT, available on request FR, ES, PL.

Features

  • Minimum invasive surgery
  • Possibility to use bipolar forceps
  • Possibility to use split neutral electrodes
  • Memorization of the last used settings
  • Power activation by pedal and/or handle
  • Digital adjustment and an indication of the output power
  • Adjustment of the acoustic indicator intensity 

Specifications

Max output power CUT  120 W - 250 Ohm
Max output power BLEND  90 W - 200 Ohm
Max output power FORCED COAG  80 W - 150 Ohm
Max output power SOFT COAG  60 W - 100 Ohm
Max output power BIPOLAR  40 W - 100 Ohm  
Working frequency  600 kHz  
Patient circuit  F
Selectable input voltage  115 - 230 Vac
Mains frequency  50 - 60 Hz  
Electrical input power  300 VA  
Size W x H x D254 x 104 x 288mm
Weight  5kgs
Controls  Patient/Plate circuit monitoring, Output power monitoring, Self-check control
Safety  EN60601-1, EN60601-1-2, EN60601-2-2
Electrical Class   I CF; MDD 93/42/EC Class: II b

Reviews (0)

There are no reviews yet.

© Copyright 2024 J.A.K Marketing Limited. All rights reserved.
J.A.K Marketing is proud to have ISO 9001 and ISO 14001 certification. ISO 9001 demonstrates our commitment to continual improvement and customer satisfaction, setting out criteria for a quality management system. ISO 14001 sets out the criteria for an environmental management system, mapping out a framework that a company or organisation can follow to set up an effective environmental management system.
© Copyright 2024 J.A.K Marketing Limited. All rights reserved.