Penlon Prima 320Advance
Variants
Item image | Item no. |
---|
Description
The Penlon Prima 320 Advance is a high-specification anaesthesia machine providing the ideal solution for today’s busy operating room.
Features
- 10.4” TFT colour touchscreen
- Eight ventilation modes
- Optional Anaesthetic Gas, N2O, COâ‚‚ and SpOâ‚‚ monitoring
- Selectatec® compatible back bar (two stations)
- LED illuminated workspaces
- Large capacity drawer units
- Optional central brake
- Switchable front-facing common gas outlet for open and closed circuit operation
- Integrated COâ‚‚ absorber and bellows unit with ventilator interface
- GCX™ compatible aluminium uprights for additional accessory mounting
- Optional auxiliary Oâ‚‚ outlet
- Three electrical outlets
Ventilator Control and Visualisation - 10.4” TFT colour touchscreen ventilator display with navigator wheel and audio/visual indicators.
Enhanced Patient Safety - Accurate mechanical anti-hypoxic device and automatic drive gas switching function.
Waveforms and Respiratory Loops - Choice of up to 10 waveform and respiratory loop displays.
Dual Flow Sensors - Inspiratory and expiratory volumes are measured and displayed on the screen.
Additional Monitoring - Optional Sidestream or Mainstream Anaesthetic Gas, and Sidestream CO2 and SpO2 monitoring.
Alarms - Audible and visual alarms with colour coding to highlight importance.
Electrical Power - Three electrical power outlets to meet your requirements.
Battery Backup - Provides power to the machine for up to 2 hours, in the event of an AC mains power failure.
Gas Supply Options - Two-cylinder yokes (O2 and N2O) and three central pipeline connections (O2, N2O and Air). O2/Air ventilator drive gas options
Auxiliary Common Gas Outlet (ACGO) - Control switch and front outlet for connecting an open breathing circuit.
Standards Compliant - Fully compliant to ISO 80601-2-13, ISO 80601-2-55, and IEC 60601-1
Ventilation Modes - Eight ventilation modes are available (VCV, PCV, PRVC, SPONT/PSV, SIMV-V, SIMV-P, SIMV-PRVC, and Manual) with PEEP available in all modes except Manual.Â
CO2 Absorber - A high-performance absorber with a ventilator interface as standard that provides ventilator mode switching, triggered by the bag/ventilator control. The unit has a built-in heating system, and the main components are autoclavable.
Anaesthesia Vaporisers - The award-winning Sigma Delta and the new Sigma EVA desflurane vaporisers offer multiple agent and filler system options to suit all clinical requirements.
Penlon Prima 320Advance
Item image | Item no. |
---|
Description
The Penlon Prima 320 Advance is a high-specification anaesthesia machine providing the ideal solution for today’s busy operating room.
Features
- 10.4” TFT colour touchscreen
- Eight ventilation modes
- Optional Anaesthetic Gas, N2O, COâ‚‚ and SpOâ‚‚ monitoring
- Selectatec® compatible back bar (two stations)
- LED illuminated workspaces
- Large capacity drawer units
- Optional central brake
- Switchable front-facing common gas outlet for open and closed circuit operation
- Integrated COâ‚‚ absorber and bellows unit with ventilator interface
- GCX™ compatible aluminium uprights for additional accessory mounting
- Optional auxiliary Oâ‚‚ outlet
- Three electrical outlets
Ventilator Control and Visualisation - 10.4” TFT colour touchscreen ventilator display with navigator wheel and audio/visual indicators.
Enhanced Patient Safety - Accurate mechanical anti-hypoxic device and automatic drive gas switching function.
Waveforms and Respiratory Loops - Choice of up to 10 waveform and respiratory loop displays.
Dual Flow Sensors - Inspiratory and expiratory volumes are measured and displayed on the screen.
Additional Monitoring - Optional Sidestream or Mainstream Anaesthetic Gas, and Sidestream CO2 and SpO2 monitoring.
Alarms - Audible and visual alarms with colour coding to highlight importance.
Electrical Power - Three electrical power outlets to meet your requirements.
Battery Backup - Provides power to the machine for up to 2 hours, in the event of an AC mains power failure.
Gas Supply Options - Two-cylinder yokes (O2 and N2O) and three central pipeline connections (O2, N2O and Air). O2/Air ventilator drive gas options
Auxiliary Common Gas Outlet (ACGO) - Control switch and front outlet for connecting an open breathing circuit.
Standards Compliant - Fully compliant to ISO 80601-2-13, ISO 80601-2-55, and IEC 60601-1
Ventilation Modes - Eight ventilation modes are available (VCV, PCV, PRVC, SPONT/PSV, SIMV-V, SIMV-P, SIMV-PRVC, and Manual) with PEEP available in all modes except Manual.Â
CO2 Absorber - A high-performance absorber with a ventilator interface as standard that provides ventilator mode switching, triggered by the bag/ventilator control. The unit has a built-in heating system, and the main components are autoclavable.
Anaesthesia Vaporisers - The award-winning Sigma Delta and the new Sigma EVA desflurane vaporisers offer multiple agent and filler system options to suit all clinical requirements.