Penlon Prima 320Advance Anaesthesia System W/ Sidestream CO2
Description
The Penlon Prima 320 Advance is a high-specification anaesthesia machine providing the ideal solution for today’s busy operating room.
Features
- 10.4” TFT colour touchscreen
- Eight ventilation modes
- Optional Anaesthetic Gas, N2O, CO₂ and SpO₂ monitoring
- Selectatec® compatible back bar (two stations)
- LED illuminated workspaces
- Large capacity drawer units
- Optional central brake
- Switchable front-facing common gas outlet for open and closed circuit operation
- Integrated CO₂ absorber and bellows unit with ventilator interface
- GCX™ compatible aluminium uprights for additional accessory mounting
- Optional auxiliary O₂ outlet
- Three electrical outlets
Ventilator Control and Visualisation - 10.4” TFT colour touchscreen ventilator display with navigator wheel and audio/visual indicators.
Enhanced Patient Safety - Accurate mechanical anti-hypoxic device and automatic drive gas switching function.
Waveforms and Respiratory Loops - Choice of up to 10 waveform and respiratory loop displays.
Dual Flow Sensors - Inspiratory and expiratory volumes are measured and displayed on the screen.
Additional Monitoring - Optional Sidestream or Mainstream Anaesthetic Gas, and Sidestream CO2 and SpO2 monitoring.
Alarms - Audible and visual alarms with colour coding to highlight importance.
Electrical Power - Three electrical power outlets to meet your requirements.
Battery Backup - Provides power to the machine for up to 2 hours, in the event of an AC mains power failure.
Gas Supply Options - Two-cylinder yokes (O2 and N2O) and three central pipeline connections (O2, N2O and Air). O2/Air ventilator drive gas options
Auxiliary Common Gas Outlet (ACGO) - Control switch and front outlet for connecting an open breathing circuit.
Standards Compliant - Fully compliant to ISO 80601-2-13, ISO 80601-2-55, and IEC 60601-1
Ventilation Modes - Eight ventilation modes are available (VCV, PCV, PRVC, SPONT/PSV, SIMV-V, SIMV-P, SIMV-PRVC, and Manual) with PEEP available in all modes except Manual.
CO2 Absorber - A high-performance absorber with a ventilator interface as standard that provides ventilator mode switching, triggered by the bag/ventilator control. The unit has a built-in heating system, and the main components are autoclavable.
Anaesthesia Vaporisers - The award-winning Sigma Delta and the new Sigma EVA desflurane vaporisers offer multiple agent and filler system options to suit all clinical requirements.
Reviews (0)
There are no reviews yet.
Penlon Prima 320Advance Anaesthesia System W/ Sidestream CO2
Description
The Penlon Prima 320 Advance is a high-specification anaesthesia machine providing the ideal solution for today’s busy operating room.
Features
- 10.4” TFT colour touchscreen
- Eight ventilation modes
- Optional Anaesthetic Gas, N2O, CO₂ and SpO₂ monitoring
- Selectatec® compatible back bar (two stations)
- LED illuminated workspaces
- Large capacity drawer units
- Optional central brake
- Switchable front-facing common gas outlet for open and closed circuit operation
- Integrated CO₂ absorber and bellows unit with ventilator interface
- GCX™ compatible aluminium uprights for additional accessory mounting
- Optional auxiliary O₂ outlet
- Three electrical outlets
Ventilator Control and Visualisation - 10.4” TFT colour touchscreen ventilator display with navigator wheel and audio/visual indicators.
Enhanced Patient Safety - Accurate mechanical anti-hypoxic device and automatic drive gas switching function.
Waveforms and Respiratory Loops - Choice of up to 10 waveform and respiratory loop displays.
Dual Flow Sensors - Inspiratory and expiratory volumes are measured and displayed on the screen.
Additional Monitoring - Optional Sidestream or Mainstream Anaesthetic Gas, and Sidestream CO2 and SpO2 monitoring.
Alarms - Audible and visual alarms with colour coding to highlight importance.
Electrical Power - Three electrical power outlets to meet your requirements.
Battery Backup - Provides power to the machine for up to 2 hours, in the event of an AC mains power failure.
Gas Supply Options - Two-cylinder yokes (O2 and N2O) and three central pipeline connections (O2, N2O and Air). O2/Air ventilator drive gas options
Auxiliary Common Gas Outlet (ACGO) - Control switch and front outlet for connecting an open breathing circuit.
Standards Compliant - Fully compliant to ISO 80601-2-13, ISO 80601-2-55, and IEC 60601-1
Ventilation Modes - Eight ventilation modes are available (VCV, PCV, PRVC, SPONT/PSV, SIMV-V, SIMV-P, SIMV-PRVC, and Manual) with PEEP available in all modes except Manual.
CO2 Absorber - A high-performance absorber with a ventilator interface as standard that provides ventilator mode switching, triggered by the bag/ventilator control. The unit has a built-in heating system, and the main components are autoclavable.
Anaesthesia Vaporisers - The award-winning Sigma Delta and the new Sigma EVA desflurane vaporisers offer multiple agent and filler system options to suit all clinical requirements.
Reviews (0)
There are no reviews yet.